Baghouse Filter Calculator

Air to Cloth Ratio       Can Velocity
Enter the ACFM of Air ÷ Sq. Ft. of Cloth
Then Click on Calculate To Find the Air to Cloth Ratio

ACFM  ÷ Sq. Ft of Cloth 

 

Air to Cloth Ratio  to 1                  

Enter ACFM of Air ÷ ( Side L (in.) X Side w (in.))

                                         144 sq. in / sq. ft.

Then Click on Calculate To Find the Can Velocity

ACFM  ÷ ( Side L   Side W )

                                       ———————————–

144 sq. in / sq. ft.

Can Velocity =  FPM                                     

Cloth Area
Air to Cloth Ratio  to 1 x ACFM Sq. Ft of Cloth                          

Enter  (Bag Dia. X  π X Length of Cages X # of Bags)

                                      144 sq. in / sq. ft.

Then Click on Calculate To Find the Cloth Area

Bag Dia. 

π X Length of Cage 

X # of Bags 

————————————————————————————–

                                          144 sq. in / sq. ft.

Cloth Area =  Sq. Ft.                                        

Air to Cloth Ratio to 1 x Sq. Ft of Cloth 

ACFM                                      

Interstitial Velocity

Enter  ACFM of Air ÷ ( Side L (in.) X Side w (in.)) ((Bag Dia.÷2)² X  π  X # of Bags

                                              144 sq. in / sq. ft.                   144 sq. in / sq. ft.

Then Click on Calculate To Find the Interstitial Velocity

 

ACFM  ÷ ( Side L  X  Side W )-Bag Dia.   X π X # of Bags 

                                    ———————————————      ———————————————-

                                                      144 sq. in / sq. ft.                             144 sq. in / sq. ft.

Interstitial Velocity =  FPM